Timber Floors in Laundries Without Tiles Alternative Flooring When design meets compliance NCC 2022 Volume 2 Area of NCC Requirements: H4P1 – Wet areas Housing Provisions Part 10.2 The Challenge Laundry floors are treated as wet areas becaus... 16 Mar 2026
Valley Gutters and Commercial Buildings Constrained Roof Designs Box gutter compliance NCC 2022 Volume 1 Area of NCC Requirements: F1P3 - Roof drainage AS/NZS 3500.3:2021 – Stormwater Drainage The Challenge Some buildings simply don’t have ... 16 Mar 2026
Bushfire Fire Safety - Commercial Building Fire Engineering in Class 9b Buildings When the NCC Doesn’t Fit Neatly NCC 2022, Volume 1 Area of NCC Requirements: Part C The Challenge Designing fire safety measures for a Class 9b building in a bus... 16 Mar 2026
Pedestal Pavers at External Sliding Doors Threshold Heights Surface finishes that impact weatherproofing NCC 2022, Volume 2 Area of NCC Requirements: H2P1 – Rainwater managment HP 3.3.3 (b) (ii) - Drainage The Challenge Pedestal paver systems... 23 Jan 2026
Cladding for Childcare Buildings Lightweight Cladding Coversion Weatherboard usage on class 9b buildings NCC 2022 Volume One Area of NCC Requirements: Section F – Health Amenity F3P1 – Weatherproofing of External Walls F3D1 – Deemed-... 23 Jan 2026
Secure Areas and Disability Access Access to All Parts of a Building Swipe access and DDA requirements NCC 2022 Volume 1 Amendment 2 Area of NCC Requirements: D1P1 – Acces for people with a disability D4D2, D4D3 D4D4 The Challenge In ... 23 Jan 2026
S.I.P's Panels - Alternative Wall Types Compressed-straw S.I.P's Panel Structural compliance in portable homes NCC 2022 Volume 2 Area of NCC Requirements: H1P1 – Structural Reliability Termite Management H4P1 – Wet Area Waterproofing H4P7 /... 14 Dec 2025
Room Heights less than 2.4m Bedroom Room Ceiling Heights Performance based alternatives NCC 2007 Volume 2 Area of NCC Requirements: P2.4.2 – Room Heights Section F3 – Room Heights (BCA Guide) The Challenge Minimum ceiling height... 14 Dec 2025
Eliminating Secondary Floor Waste Unenclosed Shower Secondary floor waste alternatives NCC 2022 Volume 2 Area of NCC Requirements: H4P1 – Wet Areas H4D2 – Wet Area Waterproofing AS 3740:2021 – Waterproofing of Domestic Wet Areas The C... 14 Dec 2025
Smarter Termite Management Termite Baiting Alternative Robust reliable perimeter protection NCC 2022 Volume 2 Area of NCC Requirements: QLD H1P3 – Termite Management Measures ABCB Part 3.4 – Termite Risk Management The Challeng... 29 Sept 2025
Accessible Bathroom With Dual Floor Wastes Drainage Falls Dual floor waste floor grading NCC 2022 Volume 1 Area of NCC Requirements: F4P1 – Personal Hygiene Facilities F4D5 – Accessible Sanitary Facilities The Challenge Bathrooms in commercial... 22 Sept 2025
Box Gutters and Stormwater - Non Standard Sizes Box Gutters and Stormwater Non standard sizes NCC 2016 Volume 2 Area of NCC Requirements: DP1.1 – Roof Drainage Systems DP1.2 – Overflow Devices DP1.3 – Watertightness DP1.4 – Roof Drainage Installati... 22 Sept 2025